Tankless water heater sizing guide and calculator

Our tankless water heater size calculator turns the fixtures you use at the same time and your climate into the flow rate, temperature rise, gas BTU and electric kW you need.

Updated November 5, 2026 · 4 min read · By Tankless Water Heater Shop Editorial Team · How we write guides

Key takeaways

  • Tankless sizing comes down to two numbers: flow (GPM) of the fixtures you run at once, and temperature rise from your coldest incoming water to your set temperature.
  • A unit’s headline GPM is usually measured at a small rise; check the flow at your rise.
  • Most two-bathroom homes need about 5–7 GPM, which means roughly 160,000–199,000 BTU gas or 27–36 kW electric in warm climates.

Tankless water heater size calculator

How many of each fixture run at the same time?

0GPM needed
0Temperature rise (°F)
0Gas BTU input (condensing)
0Electric kW

The calculator uses standard formulas: gas input BTU/h = GPM × 500 × temperature rise ÷ efficiency (0.95 condensing, 0.82 non-condensing), and electric kW = GPM × temperature rise × 0.1465. It is an estimate. Check the product page and manual, and ask your installer to confirm.

Step 1: Add up your peak flow (GPM)

This is the core of how to size a tankless water heater: you calculate size of tankless water heater needs from flow and temperature rise, not tank gallons.

Tankless water heaters are sized by gallons per minute (GPM) at peak demand, not by gallons stored. List the hot-water fixtures your household realistically uses at the same time.

Fixture Typical hot water flow
Shower (federal max 2.5 GPM) 1.5–2.5 GPM
Bathroom faucet 0.5–1.5 GPM
Kitchen faucet 1.5–2.2 GPM
Dishwasher 1.0–1.5 GPM
Washing machine (warm) 1.5–2.0 GPM
Bathtub filling 4.0+ GPM

Hot water is mixed with cold at the tap, so a 2.0 GPM shower usually draws less than 2.0 GPM of hot water. The calculator uses full fixture flow as a safety margin.

Step 2: Find your temperature rise

Temperature rise = the temperature you want (usually 105–120°F) minus the temperature of the water entering your home in winter. Groundwater in the northern U.S. can be near 40°F in winter; along the Gulf Coast and in Florida it can be 65–75°F. That difference changes how much a unit can deliver.

Region Winter inlet water Rise to 120°F
Northern states 37–45°F 75–83°F
Central states 47–55°F 65–73°F
Southern states 57–65°F 55–63°F
Florida, south Texas, Arizona low desert 65–75°F 45–55°F

Step 3: Match flow and rise to a unit

Manufacturers publish a flow chart showing GPM at different rises. A unit marketed as "11 GPM" may deliver that only at about a 35°F rise. Use the flow at your rise.

Tankless water heater sizing chart (gas and propane)

BTU input (condensing) GPM at 45°F rise GPM at 60°F rise GPM at 75°F rise
120,000 5.1 3.8 3.0
150,000 6.3 4.8 3.8
180,000 7.6 5.7 4.6
199,000 8.4 6.3 5.0

Electric tankless sizing chart

Electric kW GPM at 45°F rise GPM at 60°F rise GPM at 75°F rise Approx. amps at 240V
13 kW 2.0 1.5 1.2 54 A
18 kW 2.7 2.0 1.6 75 A
27 kW 4.1 3.1 2.5 113 A
36 kW 5.5 4.1 3.3 150 A

Values are calculated, rounded and assume 95% efficiency for gas. Real-world performance varies by model.

An 8 GPM tankless water heater or 10 GPM tankless water heater rating is a maximum; use the tankless water heater size chart below to see what you’ll actually get. If you were comparing against a 10 gallon electric water heater mini tank, note that a mini tank serves one fixture briefly, while these units serve the whole house.

Sizing examples

Common sizing mistakes

  1. Using the maximum GPM rating instead of the flow at your rise.
  2. Sizing for summer, when inlet water is warmer, instead of winter.
  3. Counting a bathtub when you rarely fill it. Tubs need high flow; plan for them only if you use them.
  4. Ignoring gas supply. A 199,000 BTU unit needs a gas line sized for it. See installation requirements.
  5. Ignoring electrical capacity for electric units. A 36 kW unit needs about 150 amps.

Still deciding on fuel? Read gas vs electric tankless water heaters.

Got your number?

Filter whole-house units by the GPM and fuel the calculator recommends. Or send us your results and we’ll double-check them.

Shop by size

Frequently asked questions

How big of a tankless water heater do I need?

Add up the GPM of the fixtures you use at once (for example, two showers at 2 GPM plus a faucet at 1 GPM = 5 GPM), then find a unit that delivers that flow at your winter temperature rise. The calculator above does it for you.

What size tankless water heater do I need for a family of 4?

Usually 5–7 GPM at your temperature rise. That is typically a 180,000–199,000 BTU gas or propane unit, or a 27–36 kW electric unit if you live in a warm climate.

Is a 10 GPM tankless water heater enough?

A unit rated 10–11 GPM is usually rated at a small temperature rise. At a 70°F rise in a cold climate, the same unit typically delivers about 5–5.5 GPM, enough for two showers and a faucet.

Can a tankless water heater pump more GPM?

No, the heater does not boost water pressure. Flow is limited by its heating capacity. If you need more hot water flow, choose a larger unit, link two units, or reduce simultaneous demand with low-flow fixtures.

What tankless water heater is equivalent to a 50-gallon tank?

There is no direct gallon equivalent because tankless units never run out. For a home that used a 50-gallon tank, a 150,000–199,000 BTU gas unit (about 5–8 GPM at typical rises) is the usual replacement.

This guide is general information for U.S. homeowners, not professional advice. Gas, electrical and venting work must follow the manufacturer’s instructions and local codes, and in most areas requires a licensed plumber, electrician or gas fitter and a permit. Specifications and prices change; always confirm details on the product page and in the installation manual.